Products

Products

Browse LITE air, process-gas, air-driven liquid and specialty booster pumps. Compare available specifications and select by medium, drive conditions and duty point.

24 equipment results

LITE DGM03 Air Booster Pump product image

Air Pressure Boosters

LITE DGM03 Air Booster Pump

DGM03 is a single-acting air booster for local boosting of clean compressed air. Its nominal 3:1 ratio supports selection for pneumatic fixtures and test-station air supplies.

Medium
Clean compressed air
LITE 2DGD Series Dual-Drive Gas Booster Pumps product image

Gas Booster Pumps

LITE 2DGD Series Dual-Drive Gas Booster Pumps

2DGD uses a double-acting, dual-drive-cylinder design to further boost pre-pressurized process gas. Select the gas and operating point for transfer, filling or leak-test gas supply systems.

Pressure
Maximum outlet pressure 8–48 MPa, depending on model
Medium
Process gas; gas-contact components matched to the actual medium
LITE 250 mm Drive Bore High-Flow Air-Driven Liquid Booster Pump product image

Liquid Booster Pumps

LITE 250 mm Drive Bore High-Flow Air-Driven Liquid Booster Pump

This custom liquid booster uses a 250 mm air-drive cylinder. Configuration depends on required flow at the target pressure, available drive air and liquid inlet supply.

Pressure
See the selection table for reference outlet pressure; confirm duty point for the model and configuration
Medium
Liquids; select for the specific medium, composition and temperature
LITE ALM02 Air Pressure Booster product image

Air Pressure Boosters

LITE ALM02 Air Pressure Booster

ALM02 uses compressed-air drive to provide locally boosted air for pneumatic clamps, actuators and leak-test stations. Its 2:1 boost ratio supports selection around an existing compressed-air supply.

Medium
Clean compressed air
LITE LTGPV Series Air Pressure Booster Pumps product image

Air Pressure Boosters

LITE LTGPV Series Air Pressure Booster Pumps

LTGPV boosts compressed air locally with a choice of 2:1 and 5:1 ratios. Select the model from the available air supply and required pressure, then match piping and air storage to the usage cycle.

Medium
Clean compressed air
LITE DGV08 Air Booster Pump product image

Air Pressure Boosters

LITE DGV08 Air Booster Pump

DGV08 is a single-acting air booster for local boosting of clean compressed air. Its nominal 8:1 ratio supports selection for pneumatic fixtures and test-station air supplies.

Medium
Clean compressed air
LITE LTA Series Gas Booster Pumps product image

Gas Booster Pumps

LITE LTA Series Gas Booster Pumps

LTA uses a single-acting design with air-operated reversal for reciprocating gas boosting. Select a model for gas pressure build-up and pressure-holding systems using the gas type, inlet pressure and flow at the target pressure.

Pressure
Maximum outlet pressure 1.6–80 MPa, depending on model
Medium
Process gas; gas-contact components matched to the actual medium
LITE LTD Series Gas Booster Pumps product image

Gas Booster Pumps

LITE LTD Series Gas Booster Pumps

LTD uses a single-stage, dual-head design for boosting gas supplied at a positive inlet pressure. Its pressure relation includes inlet pressure, so gas supply and drive-air conditions must be checked together.

Pressure
Maximum outlet pressure 8–140 MPa, depending on model
Medium
Process gas; gas-contact components matched to the actual medium
LITE LTT Series Two-Stage Gas Booster Pumps product image

Gas Booster Pumps

LITE LTT Series Two-Stage Gas Booster Pumps

LTT uses two-stage compression to raise inlet gas to the required pressure. Model selection can accommodate low inlet-pressure supplies; check the individual inlet pressure range for each model.

Pressure
Maximum outlet pressure 20–80 MPa, depending on model
Medium
Process gas; gas-contact components matched to the actual medium
LITE LA Series Air-Driven Liquid Pumps product image

Liquid Booster Pumps

LITE LA Series Air-Driven Liquid Pumps

LA pumps use an 80 mm air-drive piston for liquid boosting, pressure testing and equipment integration. Select a model for the liquid and the required pressure and flow.

Pressure
See the selection table for reference outlet pressure; confirm duty point for the model and configuration
Medium
Liquids; select for the specific medium, composition and temperature
LITE LB Series Air-Driven Liquid Pumps product image

Liquid Booster Pumps

LITE LB Series Air-Driven Liquid Pumps

LB pumps use a 125 mm air-drive piston for liquid boosting, pressure testing, injection and pressure-holding circuits. Selection accounts for air supply, liquid inlet conditions and duty cycle.

Pressure
See the selection table for reference outlet pressure; confirm duty point for the model and configuration
Medium
Liquids; select for the specific medium, composition and temperature
LITE LBD Series Double-Acting Air-Driven Liquid Pumps product image

Liquid Booster Pumps

LITE LBD Series Double-Acting Air-Driven Liquid Pumps

LBD pumps combine a 125 mm air-drive piston with a double-acting configuration for liquid boosting and pressure testing. Match the model and air supply to flow at the target pressure and the duty cycle.

Pressure
See the selection table for reference outlet pressure; confirm duty point for the model and configuration
Medium
Liquids; select for the specific medium, composition and temperature
LITE LTG Series Air-Driven Liquid Pumps outline dimension reference

Liquid Booster Pumps

LITE LTG Series Air-Driven Liquid Pumps

LTG air-driven liquid pumps offer a choice of pressure ratios for liquid boosting and pressure-test circuits. Select by target pressure, liquid inlet conditions and duty cycle.

Pressure
See the selection table for reference outlet pressure; confirm duty point for the model and configuration
Medium
Liquids; select for the specific medium, composition and temperature
LITE LTGD Series Air-Driven Liquid Pumps outline dimension reference

Liquid Booster Pumps

LITE LTGD Series Air-Driven Liquid Pumps

LTGD air-driven liquid pumps offer a choice of pressure ratios for liquid boosting and pressure-test equipment. Match pressure and flow requirements to the available air and liquid supply.

Pressure
See the selection table for reference outlet pressure; confirm duty point for the model and configuration
Medium
Liquids; select for the specific medium, composition and temperature
LITE LTG-2 Series Air-Driven Liquid Pumps outline dimension reference

Liquid Booster Pumps

LITE LTG-2 Series Air-Driven Liquid Pumps

LTG-2 air-driven pumps serve high-pressure, low-flow liquid boosting applications. Select the model and system configuration for target pressure, liquid conditions and duty cycle.

Pressure
See the selection table for reference outlet pressure; confirm duty point for the model and configuration
Medium
Liquids; select for the specific medium, composition and temperature
LITE Hydraulically Driven Liquid Intensifier product image

Liquid Booster Pumps

LITE Hydraulically Driven Liquid Intensifier

A hydraulic power source drives the reciprocating piston and plunger to supply high-pressure liquid for pressure testing, pressure cycling and pulse fatigue tests. Configuration follows the power source and test cycle.

Pressure
See the selection table for reference outlet pressure; confirm duty point for the model and configuration
Medium
Liquids; select for the specific medium, composition and temperature
RP04-06NL Gaseous Refrigerant Booster Pump product image

Specialty Booster Pumps

RP04-06NL Gaseous Refrigerant Booster Pump

RP04-06NL uses compressed air to boost and transfer gaseous refrigerants and support recovery arrangements. The refrigerant designation, inlet temperature and pressure determine the medium-side configuration and duty point.

Medium
Gaseous refrigerant; designation confirmed for the configuration
Air-Driven Hydrogen Booster Configuration product image

Specialty Booster Pumps

Air-Driven Hydrogen Booster Configuration

A selection entry for gaseous hydrogen boosting using DGA, DGD or DGT base types. Select the structure and hydrogen-contact parts for hydrogen purity, inlet pressure and flow at the target pressure.

Medium
Gaseous hydrogen
Air-Driven Dimethyl Ether Booster Configuration product image

Specialty Booster Pumps

Air-Driven Dimethyl Ether Booster Configuration

Select a DGG, DGGD or DGM base type for dimethyl ether boosting and transfer. Confirm the medium-side configuration for composition, inlet phase, temperature and target duty point.

Medium
Dimethyl ether; inlet phase confirmed for the duty
Chemical Reagent Booster Configuration product image

Specialty Booster Pumps

Chemical Reagent Booster Configuration

Select a DGG, DGGD or DGM base type for chemical reagent boosting and injection. Confirm the pump head, valves and seals for composition, concentration, phase and temperature.

Medium
Chemical reagent; composition and concentration confirmed for the duty
Sulfur Hexafluoride Booster Configuration product image

Specialty Booster Pumps

Sulfur Hexafluoride Booster Configuration

A compressed-air-driven 4:1 base type for boosting, filling, transfer and recovery of SF₆. Confirm the configuration for the medium state, inlet supply and target duty point.

Medium
Sulfur hexafluoride (SF₆)
Butane Booster Configuration product image

Specialty Booster Pumps

Butane Booster Configuration

A compressed-air-driven 4:1 base type for boosting, filling, transfer and recovery of butane. Confirm the configuration for the medium state, inlet supply and target duty point.

Medium
Butane; composition and inlet phase confirmed for the duty
Fire-Suppression Agent Filling Pump Configuration product image

Specialty Booster Pumps

Fire-Suppression Agent Filling Pump Configuration

A compressed-air-driven 6:1 base type for agent filling, transfer and recovery of fire-suppression agents. Confirm the configuration for the medium state, inlet supply and target duty point.

Medium
Fire-suppression agent; select for the actual HFC-227ea or FK-5-1-12 agent
Carbon Dioxide Booster Configuration product image

Specialty Booster Pumps

Carbon Dioxide Booster Configuration

Carbon dioxide booster configurations use C / CD plunger and WC / WCD piston base types. Select the structure and medium-side configuration for inlet phase, temperature, supply conditions and the target duty point.

Medium
Carbon dioxide; applicable phase confirmed for the base type and specific model
Compare equipment specifications
Equipment Pressure rangeWorking mediumDrive air / power sourceNominal boost ratio
LITE DGM03 Air Booster Pump —Clean compressed airNo more than 0.8 MPa recommended3:1
LITE 2DGD Series Dual-Drive Gas Booster Pumps Maximum outlet pressure 8–48 MPa, depending on modelProcess gas; gas-contact components matched to the actual medium——
LITE 250 mm Drive Bore High-Flow Air-Driven Liquid Booster Pump See the selection table for reference outlet pressure; confirm duty point for the model and configurationLiquids; select for the specific medium, composition and temperatureCompressed-air drive; confirm supply conditions for the model and application—
LITE ALM02 Air Pressure Booster —Clean compressed air0.3–0.8 MPa—
LITE LTGPV Series Air Pressure Booster Pumps —Clean compressed airLTGPV02: 0.1–0.8 MPa; LTGPV05: 0.3–0.8 MPa—
LITE DGV08 Air Booster Pump —Clean compressed airNo more than 0.8 MPa recommended8:1
LITE LTA Series Gas Booster Pumps Maximum outlet pressure 1.6–80 MPa, depending on modelProcess gas; gas-contact components matched to the actual mediumMaximum design 1.0 MPa; no more than 0.8 MPa recommended for long-term operation—
LITE LTD Series Gas Booster Pumps Maximum outlet pressure 8–140 MPa, depending on modelProcess gas; gas-contact components matched to the actual mediumNo more than 0.8 MPa recommended—
LITE LTT Series Two-Stage Gas Booster Pumps Maximum outlet pressure 20–80 MPa, depending on modelProcess gas; gas-contact components matched to the actual mediumNo more than 0.8 MPa—
LITE LA Series Air-Driven Liquid Pumps See the selection table for reference outlet pressure; confirm duty point for the model and configurationLiquids; select for the specific medium, composition and temperatureCompressed-air drive; confirm supply conditions for the model and application—
LITE LB Series Air-Driven Liquid Pumps See the selection table for reference outlet pressure; confirm duty point for the model and configurationLiquids; select for the specific medium, composition and temperatureCompressed-air drive; confirm supply conditions for the model and application—
LITE LBD Series Double-Acting Air-Driven Liquid Pumps See the selection table for reference outlet pressure; confirm duty point for the model and configurationLiquids; select for the specific medium, composition and temperatureCompressed-air drive; confirm supply conditions for the model and application—
LITE LTG Series Air-Driven Liquid Pumps See the selection table for reference outlet pressure; confirm duty point for the model and configurationLiquids; select for the specific medium, composition and temperatureCompressed-air drive; confirm supply conditions for the model and application—
LITE LTGD Series Air-Driven Liquid Pumps See the selection table for reference outlet pressure; confirm duty point for the model and configurationLiquids; select for the specific medium, composition and temperatureCompressed-air drive; confirm supply conditions for the model and application—
LITE LTG-2 Series Air-Driven Liquid Pumps See the selection table for reference outlet pressure; confirm duty point for the model and configurationLiquids; select for the specific medium, composition and temperatureCompressed-air drive; confirm supply conditions for the model and application—
LITE Hydraulically Driven Liquid Intensifier See the selection table for reference outlet pressure; confirm duty point for the model and configurationLiquids; select for the specific medium, composition and temperatureHydraulic drive, 1–10 MPa drive pressure—
RP04-06NL Gaseous Refrigerant Booster Pump —Gaseous refrigerant; designation confirmed for the configurationCompressed air; recommended 0.6–0.8 MPa, maximum 1.0 MPa—
Air-Driven Hydrogen Booster Configuration —Gaseous hydrogenCompressed air—
Air-Driven Dimethyl Ether Booster Configuration —Dimethyl ether; inlet phase confirmed for the dutyCompressed air—
Chemical Reagent Booster Configuration —Chemical reagent; composition and concentration confirmed for the dutyCompressed air—
Sulfur Hexafluoride Booster Configuration —Sulfur hexafluoride (SF₆)Compressed air—
Butane Booster Configuration —Butane; composition and inlet phase confirmed for the dutyCompressed air—
Fire-Suppression Agent Filling Pump Configuration —Fire-suppression agent; select for the actual HFC-227ea or FK-5-1-12 agentCompressed air—
Carbon Dioxide Booster Configuration —Carbon dioxide; applicable phase confirmed for the base type and specific modelCompressed air—