Overview
Equipment purpose and configuration
LITE provides pump selection, configuration and supply services for this product. The model and scope of supply are confirmed in the order.
LTD boosts gas supplied at a positive inlet pressure. Select the model using the inlet conditions, target outlet pressure and required flow at that pressure.
The series uses a single-stage, dual-head design and a 160 mm drive piston, with exhaust cooling at both pump heads. Six models offer boost ratios from 10:1 to 200:1; twin inlet and outlet piping is matched to the duty.
The tabulated pressure relation includes inlet pressure: PL is drive-air pressure, PA is gas inlet pressure and PB is outlet pressure, all in the same unit. Actual working pressure must satisfy the inlet range, pressure relation and model maximum outlet pressure. The formula does not permit exceeding the listed limit.
Features
- 6 models with boost ratios from 10:1 to 200:1
- 160 mm drive piston with exhaust cooling at both pump heads
- Twin inlet and outlet piping selected for the operating conditions
Optional Configurations
- Confirm the need and supply scope for the pump, mounting, valves, instruments, air storage and controls for the project.